TCC 1800-UE-2
Details
- TCC 1800-UE-L: Type L (Low) for use with TEST-OK 4000 BPL-UE or TEST-OK desktop enclosure
- TCC 1800-UE-H: Type H (High) for use with TEST-OK 4000 AQ-UE
Description
The TCC1800-UE-2 Test Controller Card is a versatile controller board designed for production testing of printed circuit boards. The TCC1800-UE-2 is operated via a command language and connects through Ethernet or USB. It is available in all TEST-OK single-sided, double-sided, and 19" system configurations.
The TCC1800-UE-2 supports positive voltages up to 24 V and offers extensive I/O capabilities, including analog and digital interfaces, counters, PWM outputs, bidirectional I/O, and serial, Ethernet, CAN, USB, SPI, and I²C communication. 2 adjustable Power Supplies each configurable 1.2 ... 24 VDC are included providing 45 W – 3 A each.
The TCC 1800-UE-2 is calibrated to ensure that all product specifications remain within the same tolerance range. The Ethernet connection provides galvanic isolation of the test system. The USB 2.0 High Speed (480 Mbit/s) interface is isolated, ensuring isolation of all connected devices. For all USB ports, it is possible to add a hub to connect multiple USB devices to a single USB port.
In a standard TEST-OK system, a single USB connection is provided only on the bottom module.
Connecting the TCC 1800-UE-2
It is possible to connect to the TCC1800-UE-2 via the USB port as an alternative to the connection over the Ethernet port. If needed the Ethernet port must remain connected to provide Ethernet communication to the module. A USB-over-Ethernet add-on board is available to enable USB connectivity over the Ethernet interface.
Both TCC 1800-UEA and TCC 1800-UE-2 cards have the same connection interface to the PC.
There are two ways to connect to the PC: via USB or Ethernet.
Ethernet offers the advantage that, within a local area network, the test controller card can be controlled from any PC on that network segment.
If the USB-over-Ethernet functionality is used, the USB device connected to the TCC card will also appear on the connected PC.
If this is not desired, it is possible to connect the TCC card via the galvanically isolated USB bus.
In this case, the Ethernet interface only functions as a provider of Ethernet connectivity to the UUT.
Another option is to maintain the flexibility of the network connection while connecting the USB network of the test system directly to the PC through the USB port.
To enhance the test system, various built-in options are available: A dual-output 24 VAC power supply and a configurable switch mode AC/DC power supply module providing voltages up to 0 ...50 VDC and 0 ...35 VAC.
For more complex USB configurations on the Bottom or Top Module, an integrated hub is available, offering up to ten USB ports (five ports for the Bottom Module and five ports for the Top Module).
USB options on TCC 1800-UE-2
As the demand for additional USB devices increases—not only on the bottom side of the UUT, but also on the top side—TEST-OK now introduces a fully integrated USB hub for both the bottom and top modules.
In practice, up to five devices can be connected on each side of the UUT, such as flash programmers, USB converters, cameras, and more.
For these devices, only the PCB layout towards the needed USB connectors is required—an external hub with casing and cabling is therefore unnecessary.
The USB connections also comply with the USB 2.0 High Speed (480 Mbit/s) specification. In TEST-TRACK, all connected USB devices are displayed in a tree view upon connection.
All USB ports support USB 2.0 High Speed (480 Mbit/s). On Bottom and Top module each hub provides in 2 Ampere in total for connected USB devices.
Specifications
2 Programmable Power Supplies | Power Supply 1 and 2 | 1.2 - 24 V, 3 A |
Current measurement | Resolution 1 mA - Absolute precision +/- 3 mA | 0 - 3 A |
2 Fixed Power Supplies | 5 V, 0.5 A / 28 V, 0.75 A | |
16 Analog Inputs | 0 - 24 V, 5.9 mV resolution | |
16 Analog Outputs | 0 - 24 V, 5.9 mV resolution | |
Current measurement | Resolution 1 mA | 0 - 3 A |
20 Digital Inputs with Schmitt Trigger | 1 frequency measurement/pulse counter | 0 - 24 V |
20 Digital Inputs with Schmitt Trigger | 4 pulse width/pulse counters | 0 - 24 V |
52 Digital Outputs (20 bi-directional) | 3 groups of 8 bits with programmable logic '1' level | 1.5 - 24 V |
4 'High-Side' power outputs with programmable output voltage | 5.5 - 24 V | 4 'High-Side' power outputs with programmable output voltage |
24 open collector outputs, capable of driving relays | 24 open collector outputs, capable of driving relays | |
2 PWM Outputs | 5 V, 0 - 1 MHz, 0 - 100% Duty Cycle | |
I2C Interface | ||
SPI extension interface | Additional in- and outputs | |
1 Serial Channel | UART | 5 V |
SPI interface | 78 kHz | |
CAN | 2-wire, 1-wire | |
Ethernet Ports | LAN 1 and 2 (Bezel) | 10/100/1000 Base-T Ethernet |
Ethernet Ports | TEST-OK Module | 10/100 Mbits/s |
Ethernet Ports | Expansion Board | 10/100 Mbits/s |
USB Ports over Ethernet or Direct | Module, Expansion Board, 2 Backside | USB 2.0 HS (Hub supported) |
Options and ordering
Article | Info | Order code |
TCC 1800-UE-2 | With high or low bezel | TOA025446 |
Services | ||
TCC 1800-UE Error Analysis and Report of Testparameters | Including Report of Testparameters | TOA010127 |
TCC 1800-UE Error Analysis Justification, Eeprom storage Report of Testparameters | Including Report of Testparameters | TOA013071 |